A 5,500 year old artificial human tooth from Egypt: a historical note.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):645-7
Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):648-58
Improved retention and bone-tolmplant contact with fluoride-modified titanium implants.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):659-66
Osseointegration of dental implants complexed with rhBMP-2: a comparative histomorphometric and radiographic evaluation.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):667-78
Histomorphometric analysis of homogenous demineralized dentin matrix as osteopromotive material in rabbit mandibles.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):679-86
Osteoporosis-like bone conditions affect osseointegration of implants.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):687-94
A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):695-702
Clinical evaluation of small-diameter implants in single-tooth and multiple-implant restorations: a 7-year retrospective study.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):703-9
Clinical analysis of wide-diameter frialit-2 implants.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):710-5
Clinical trial of modified ankylos implants for extraoral use in cranio- and maxillofacial surgery.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):716-20
Immediate loading of dental implants in the completely edentulous maxilla: a clinical report.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):721-30
Injury to the inferior alveolar nerve during implant placement: a formula for protection of the patient and clinician.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):731-4
Influence of superstructure materials on strain around an implant under 2 loading conditions: a technical investigation.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):735-42
Accuracy of a manual torque application device for morse-taper implants: a technical note.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):743-8
Dental rehabilitation using an implant-supported overdenture after repair of a fracture in a severely resorbed edentulous mandible: a case report.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):749-52
Distraction osteogenesis in an anterior mandibular bone defect utilizing lingual periosteal release: a case report.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):753-7
Maintaining vector control during alveolar distraction osteogenesis: a technical note.
Int J Oral Maxillofac Implants, 2004 Sep-Oct;19(5):758-62